Certified Master Inspector · Same-Day Reports · Serving Central Florida

[et_pb_section fb_built=”1″ _builder_version=”4.20.2″ _module_preset=”default” da_disable_devices=”off|off|off” global_colors_info=”{}” da_is_popup=”off” da_exit_intent=”off” da_has_close=”on” da_alt_close=”off” da_dark_close=”off” da_not_modal=”on” da_is_singular=”off” da_with_loader=”off” da_has_shadow=”on”][et_pb_row _builder_version=”4.20.2″ _module_preset=”default” custom_margin=”||15px||false|false” custom_padding=”||0px||false|false” border_radii=”on|7px|7px|7px|7px” border_width_all=”3px” border_color_all=”#000000″ global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” text_font=”|700|on|on|on||||” text_text_color=”#E02B20″ text_font_size=”47px” text_letter_spacing=”1px” text_line_height=”1.8em” text_orientation=”center” text_text_shadow_style=”preset2″ text_text_shadow_color=”#000000″ global_colors_info=”{}”]

Inspector Resource

[/et_pb_text][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” text_font=”|700|on|on|on|||#0c71c3|” text_text_color=”#0c71c3″ text_font_size=”47px” text_letter_spacing=”1px” text_line_height=”1.8em” text_orientation=”center” text_text_shadow_style=”preset2″ text_text_shadow_color=”#000000″ global_colors_info=”{}”]

MDF

[/et_pb_text][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_code][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_code][/et_pb_column][/et_pb_row][et_pb_row _builder_version=”4.20.2″ _module_preset=”default” border_radii=”on|5px|5px|5px|5px” border_width_all=”5px” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https://2020inspectionsolutions.com/wp-content/uploads/2023/12/MFD_logo_color.png” alt=”MFD logo” title_text=”MFD_logo_color” align=”center” _builder_version=”4.20.2″ _module_preset=”default” width=”53%” global_colors_info=”{}”][/et_pb_image][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” text_text_color=”#0400F0″ text_font_size=”32px” text_line_height=”1.71em” global_colors_info=”{}”]

Manufactured Home Foundation Certification Report Writing Tutorial

[/et_pb_text][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_code][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” text_font=”|||on|||||” text_font_size=”30px” text_orientation=”center” text_text_shadow_style=”preset1″ global_colors_info=”{}”]

MFD Re-Inspections

Re-Inspection’s are limited to 60 from the date of the original inspection. 

[/et_pb_text][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_code][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” hover_enabled=”0″ sticky_enabled=”0″ text_font_size=”43px” text_text_color=”#E09900″ text_font=”|700|||||||” text_orientation=”center”]

Aluminum Awning Roof Covering Narrative

[/et_pb_text][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” hover_enabled=”0″ sticky_enabled=”0″ border_width_all=”7px”] Inspection Narrative

Inspection Narrative

The inspection of the roof addition revealed that it was constructed using a lightweight aluminum pan awning material. Upon examination, it was observed that while certain load transfers may occur in connection with the manufactured home (MFD), the addition appears to exert minimal impact on the primary structural load. No significant load transfers to the MFD were identified, suggesting that the addition does not compromise structural integrity. Both the doors and windows in the area were fully functional, with no observed cracks or gaps on either the interior or exterior walls. This observation further supports the conclusion that the roof addition is not imposing any undue stress on the MFD. The overall construction and integration of the addition appear stable, and no immediate structural concerns are evident.

[/et_pb_code][et_pb_text _builder_version=”4.20.2″ _module_preset=”default” text_font=”|||on|||||” text_font_size=”30px” text_orientation=”center” text_text_shadow_style=”preset1″ global_colors_info=”{}”]

Time & Date Stamp

[/et_pb_text][et_pb_code _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_code][et_pb_image src=”https://2020inspectionsolutions.com/wp-content/uploads/2024/02/Additions-Floor-Flow-Chart.jpg” title_text=”Additions Floor Flow Chart” _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_image][et_pb_image src=”https://2020inspectionsolutions.com/wp-content/uploads/2024/02/Additions-Roof-Flow-Chart.jpg” title_text=”Additions Roof Flow Chart” _builder_version=”4.20.2″ _module_preset=”default” global_colors_info=”{}”][/et_pb_image][/et_pb_column][/et_pb_row][/et_pb_section]